AJT Equipment Roberts Testing
Test Machines   |   Digital Indicators   |   Load Cells   |   Software   |   Wire Rope Grips
Calibration & Servicing   |   Test Machine Ratings   |   Contact Us   |   Home
 
  LOAD CELLS
 

Accuway TMLoad Cell 10 VDC

Bonded foil Strain Gauge Load Cell

Standard Model Includes:

  • Type: Bonded foil strain gauge
  • Excitation: 10 VDC
  • Bridge Resistance: 350 ohms

    Specifications
    The load cell allows very accurate recording of the test load.
    The electronic strain gauge load cell is an independent measuring system not tied to the hydraulic system.
    This load cell system, with two ranges, may be calibrated from 1% to 100% of the maximum capacity of the load cell. The load cell will calibrate to ASTM E-4, +/- 1%, traceable to the United States National Institute of Standards and Technology (NBS).


Accuway TM with Handheld Readouts Accuway TM with handheld readouts
  • Handheld Readouts.
  • Made from a Lightweight Aerospace Alloy.
  • Available Hermetically sealed for use in wet conditions.
  • Units have a 5 metre cable close coupled to a 4 digit 15mm LCD display.
  • Tare, Peak and Reset facility.
  • The power source is a 9V PP3 battery, can be supplied for mains power if required (240v).
  • All units are calibrated to comply with ISO 7500-1: 2004.
  • The accuracy of the cells are better then 1% of applied load.
  • Complete with carry case.
  • 12 Month Guarantee, subject to conditions.

    Options:
    12V Mains Operation
    Monitor can be supplied with a socket for operation from a mains plug top, 240 to 12 volt power supply.
    The unit can be scaled Tonne, Kilograms or KN’s
    The above can be supplied with longer monitor cables if required
    Range of sizes we offer are: 4,000lb, 10,000lb, 20,000lb, 40,000lb, 10,000lb & 200,000lb. Plus specials

Click here for the full Accuway TM specification...
Click here to download Accuway TM specification PDF


 

Accuway CMAccuway CM with handheld readouts

  • Handheld Readouts.
  • Made from a Lightweight Aerospace Alloy.
  • Available Hermetically sealed for use in wet conditions.
  • Tare, Peak and Reset facility.
  • Units have a 5 metre cable close coupled to a 4 digit 15mm LCD display.
  • All units are calibrated to comply with ISO 7500-1: 2004.
  • The accuracy of the cells are better than 1% of applied load.
  • The power source is a 9V PP3 battery, can be supplied for mains power if required (240v).
  • 12 Month Guarantee, subject to conditions.
  • Complete with carry case.

    Options:
    12V Mains Operation
    Monitor can be supplied with a socket for operation from a mains plug top, 240 to 12 volt power supply.
    The unit can be scaled Tonne, Kilograms or KN’s
    The above can be supplied with longer monitor cables if required
    Range of sizes we offer are: 2.0 tonne, 5.0 tonne, 10.0 tonne, 20.0 tonne, 50.0 tonne & 100.0 tonne. Plus specials

Click here for the full Accuway CM specification...
Click here to download Accuway CM specification PDF

 


 

Accuway SRWAccuway TMIR - Infrared Operation

  • The cell is manufactured in aluminium alloy with HT steel bushes.
  • The cell incorporates an eight gauge bridge together with associated electronics and a 9 volt PP3 non-rechargeable battery.
  • Built into the load cell is a large [20mm] 3.5 digit liquid crystal display mounted on the front of the cell for easy reading from the operator’s position.
  • The load cell is self contained and has no external cabling.
  • A battery switch is provided on the rear of the cell to prolong battery life when the cell is out of use.
  • All set up and calibration data is retained when switched off.
  • The cell is automatically switched off after 15 minutes to prolong battery life.
  • Battery life – typically 50 hours.

    Note :- The tare and peak readings are stored even after an automatic 15 minute shut down, the tare and peak reading being returned at next ‘on’ press of the remote, [provided the cell rear button has not been switched off.] * Automatic range change is available when appropriate.
Dimensions
Capacity Length Width Depth Hole Dia. Hole Centres
10,000lb 10.82" 3.93" 1.97" 1.02" 7.87"
20,000lb 12.99" 4.33" 1.97" 1.42" 8.66"
40,000lb 14.17" 5.51" 1.97" 2.05" 9.45"
100,000lb 17.40" 6.23" 2.95" 2.83" 10.70"

 

Accuway TMIR RemoteAccuway TMIR - Infrared Operation

  • Control is via a hand held controller.
  • Size – 95 x 60 x 40 mm.
  • Battery – 1 x PP3 non-rechargeable
  • Battery life – many tens/hundreds of hours depending on use.
  • Mounted on the controller are four momentary action push buttons. These buttons perform the following functions :- On/Off.
  • Zero/Tare – button will tare up to 10% of cell capacity.
  • Peak – retains the highest load applied since selecting Peak or resetting.
  • Reset – resets the peak reading
  • Range – The infrared controller will operate in bright ambient light conditions, however, it will not operate if the cell is directly facing into the sun.
  • The minimum range is 5 metres, typically 7 metres.

Click here to download Accuway TMIR specification PDF


Accuway SMIRAccuway SMIR - Infrared Operation

  • The cell is manufactured in aluminium alloy with HT steel bushes.
  • The cell incorporates an eight gauge bridge together with associated electronics and a 9 volt PP3 non-rechargeable battery.
  • Built into the load cell is a large [20mm] 3.5 digit liquid crystal display mounted on the front of the cell for easy reading from the operator’s position.
  • The load cell is self contained and has no external cabling.
  • A battery switch is provided on the rear of the cell to prolong battery life when the cell is out of use.
  • All set up and calibration data is retained when switched off.
  • The cell is automatically switched off after 15 minutes to prolong battery life.
  • Battery life – typically 50 hours.
  • Available in 4,000lb, 10,000lb & 20,000lb

    Note :- The tare and peak readings are stored even after an automatic 15 minute shut down, the tare and peak reading being returned at next ‘on’ press of the remote, [provided the cell rear button has not been switched off.] * Automatic range change is available when appropriate.

 










Accuway SMIR RemoteAccuway SMIR - Infrared Operation

  • Control is via a hand held controller.
  • Size – 95 x 60 x 40 mm.
  • Battery – 1 x PP3 non-rechargeable
  • Battery life – many tens/hundreds of hours depending on use.
  • Mounted on the controller are four momentary action push buttons. These buttons perform the following functions :- On/Off.
  • Zero/Tare – button will tare up to 10% of cell capacity.
  • Peak – retains the highest load applied since selecting Peak or resetting.
  • Reset – resets the peak reading
  • Range – The infrared controller will operate in bright ambient light conditions, however, it will not operate if the cell is directly facing into the sun.
  • The minimum range is 5 metres, typically 7 metres.

Click here to download Accuway smir specification PDF

   

Test Machines   |   Digital Indicators   |   Load Cells   |   Software   |   Wire Rope Grips   |   Calibration & Servicing   |   Contact Us   |   Home
AJT Equipment (USA) Inc (Roberts Testing) . P.O. Box 2272 Savannah, GA 31498
Tel: (912) 964-9465   |   Fax: (912) 964-9420   |   email: query@RobertsTesting.com  |   admin@robertstesting.com
Part of the AJT Equipment Ltd Group of Companies: www.ajt-testing.com   |   www.robertstesting.com Site Design: Charles Design
  .....................................